mirror of
https://github.com/Polprzewodnikowy/SummerCart64.git
synced 2024-12-26 04:51:56 +01:00
225 lines
8.0 KiB
Verilog
Vendored
225 lines
8.0 KiB
Verilog
Vendored
module serv_state
|
|
#(parameter RESET_STRATEGY = "MINI",
|
|
parameter [0:0] WITH_CSR = 1,
|
|
parameter [0:0] ALIGN =0,
|
|
parameter [0:0] MDU = 0,
|
|
parameter W = 1
|
|
)
|
|
(
|
|
input wire i_clk,
|
|
input wire i_rst,
|
|
//State
|
|
input wire i_new_irq,
|
|
input wire i_alu_cmp,
|
|
output wire o_init,
|
|
output reg o_cnt_en,
|
|
output wire o_cnt0to3,
|
|
output wire o_cnt12to31,
|
|
output wire o_cnt0,
|
|
output wire o_cnt1,
|
|
output wire o_cnt2,
|
|
output wire o_cnt3,
|
|
output wire o_cnt7,
|
|
output wire o_cnt_done,
|
|
output wire o_bufreg_en,
|
|
output wire o_ctrl_pc_en,
|
|
output reg o_ctrl_jump,
|
|
output wire o_ctrl_trap,
|
|
input wire i_ctrl_misalign,
|
|
input wire i_sh_done,
|
|
input wire i_sh_done_r,
|
|
output wire [1:0] o_mem_bytecnt,
|
|
input wire i_mem_misalign,
|
|
//Control
|
|
input wire i_bne_or_bge,
|
|
input wire i_cond_branch,
|
|
input wire i_dbus_en,
|
|
input wire i_two_stage_op,
|
|
input wire i_branch_op,
|
|
input wire i_shift_op,
|
|
input wire i_sh_right,
|
|
input wire i_slt_or_branch,
|
|
input wire i_e_op,
|
|
input wire i_rd_op,
|
|
//MDU
|
|
input wire i_mdu_op,
|
|
output wire o_mdu_valid,
|
|
//Extension
|
|
input wire i_mdu_ready,
|
|
//External
|
|
output wire o_dbus_cyc,
|
|
input wire i_dbus_ack,
|
|
output wire o_ibus_cyc,
|
|
input wire i_ibus_ack,
|
|
//RF Interface
|
|
output wire o_rf_rreq,
|
|
output wire o_rf_wreq,
|
|
input wire i_rf_ready,
|
|
output wire o_rf_rd_en);
|
|
|
|
reg stage_two_req;
|
|
reg init_done;
|
|
wire misalign_trap_sync;
|
|
|
|
reg [4:2] o_cnt;
|
|
reg [3:0] cnt_r;
|
|
|
|
reg ibus_cyc;
|
|
//Update PC in RUN or TRAP states
|
|
assign o_ctrl_pc_en = o_cnt_en & !o_init;
|
|
|
|
assign o_mem_bytecnt = o_cnt[4:3];
|
|
|
|
assign o_cnt0to3 = (o_cnt[4:2] == 3'd0);
|
|
assign o_cnt12to31 = (o_cnt[4] | (o_cnt[3:2] == 2'b11));
|
|
assign o_cnt0 = (o_cnt[4:2] == 3'd0) & cnt_r[0];
|
|
assign o_cnt1 = (o_cnt[4:2] == 3'd0) & cnt_r[1];
|
|
assign o_cnt2 = (o_cnt[4:2] == 3'd0) & cnt_r[2];
|
|
assign o_cnt3 = (o_cnt[4:2] == 3'd0) & cnt_r[3];
|
|
assign o_cnt7 = (o_cnt[4:2] == 3'd1) & cnt_r[3];
|
|
|
|
//Take branch for jump or branch instructions (opcode == 1x0xx) if
|
|
//a) It's an unconditional branch (opcode[0] == 1)
|
|
//b) It's a conditional branch (opcode[0] == 0) of type beq,blt,bltu (funct3[0] == 0) and ALU compare is true
|
|
//c) It's a conditional branch (opcode[0] == 0) of type bne,bge,bgeu (funct3[0] == 1) and ALU compare is false
|
|
//Only valid during the last cycle of INIT, when the branch condition has
|
|
//been calculated.
|
|
wire take_branch = i_branch_op & (!i_cond_branch | (i_alu_cmp^i_bne_or_bge));
|
|
|
|
//valid signal for mdu
|
|
assign o_mdu_valid = MDU & !o_cnt_en & init_done & i_mdu_op;
|
|
|
|
//Prepare RF for writes when everything is ready to enter stage two
|
|
// and the first stage didn't cause a misalign exception
|
|
assign o_rf_wreq = !misalign_trap_sync & !o_cnt_en & init_done &
|
|
((i_shift_op & (i_sh_done | !i_sh_right)) |
|
|
i_dbus_ack | (MDU & i_mdu_ready) |
|
|
i_slt_or_branch);
|
|
|
|
assign o_dbus_cyc = !o_cnt_en & init_done & i_dbus_en & !i_mem_misalign;
|
|
|
|
//Prepare RF for reads when a new instruction is fetched
|
|
// or when stage one caused an exception (rreq implies a write request too)
|
|
assign o_rf_rreq = i_ibus_ack | (stage_two_req & misalign_trap_sync);
|
|
|
|
assign o_rf_rd_en = i_rd_op & !o_init;
|
|
|
|
/*
|
|
bufreg is used during mem. branch and shift operations
|
|
|
|
mem : bufreg is used for dbus address. Shift in data during phase 1.
|
|
Shift out during phase 2 if there was an misalignment exception.
|
|
|
|
branch : Shift in during phase 1. Shift out during phase 2
|
|
|
|
shift : Shift in during phase 1. Continue shifting between phases (except
|
|
for the first cycle after init). Shift out during phase 2
|
|
*/
|
|
assign o_bufreg_en = (o_cnt_en & (o_init | ((o_ctrl_trap | i_branch_op) & i_two_stage_op))) | (i_shift_op & !stage_two_req & (i_sh_right | i_sh_done_r) & init_done);
|
|
|
|
assign o_ibus_cyc = ibus_cyc & !i_rst;
|
|
|
|
assign o_init = i_two_stage_op & !i_new_irq & !init_done;
|
|
|
|
assign o_cnt_done = (o_cnt[4:2] == 3'b111) & cnt_r[3];
|
|
|
|
always @(posedge i_clk) begin
|
|
//ibus_cyc changes on three conditions.
|
|
//1. i_rst is asserted. Together with the async gating above, o_ibus_cyc
|
|
// will be asserted as soon as the reset is released. This is how the
|
|
// first instruction is fetced
|
|
//2. o_cnt_done and o_ctrl_pc_en are asserted. This means that SERV just
|
|
// finished updating the PC, is done with the current instruction and
|
|
// o_ibus_cyc gets asserted to fetch a new instruction
|
|
//3. When i_ibus_ack, a new instruction is fetched and o_ibus_cyc gets
|
|
// deasserted to finish the transaction
|
|
if (i_ibus_ack | o_cnt_done | i_rst)
|
|
ibus_cyc <= o_ctrl_pc_en | i_rst;
|
|
|
|
if (o_cnt_done) begin
|
|
init_done <= o_init & !init_done;
|
|
o_ctrl_jump <= o_init & take_branch;
|
|
end
|
|
|
|
//Need a strobe for the first cycle in the IDLE state after INIT
|
|
stage_two_req <= o_cnt_done & o_init;
|
|
|
|
if (i_rst) begin
|
|
if (RESET_STRATEGY != "NONE") begin
|
|
init_done <= 1'b0;
|
|
o_ctrl_jump <= 1'b0;
|
|
stage_two_req <= 1'b0;
|
|
end
|
|
end
|
|
end
|
|
|
|
always @(posedge i_clk) begin
|
|
/*
|
|
Because SERV is 32-bit bit-serial we need a counter than can count 0-31
|
|
to keep track of which bit we are currently processing. o_cnt and cnt_r
|
|
are used together to create such a counter.
|
|
The top three bits (o_cnt) are implemented as a normal counter, but
|
|
instead of the two LSB, cnt_r is a 4-bit shift register which loops 0-3
|
|
When cnt_r[3] is 1, o_cnt will be increased.
|
|
|
|
The counting starts when the core is idle and the i_rf_ready signal
|
|
comes in from the RF module by shifting in the i_rf_ready bit as LSB of
|
|
the shift register. Counting is stopped by using o_cnt_done to block the
|
|
bit that was supposed to be shifted into bit 0 of cnt_r.
|
|
|
|
There are two benefit of doing the counter this way
|
|
1. We only need to check four bits instead of five when we want to check
|
|
if the counter is at a certain value. For 4-LUT architectures this means
|
|
we only need one LUT instead of two for each comparison.
|
|
2. We don't need a separate enable signal to turn on and off the counter
|
|
between stages, which saves an extra FF and a unique control signal. We
|
|
just need to check if cnt_r is not zero to see if the counter is
|
|
currently running
|
|
*/
|
|
if (W == 4) begin
|
|
if (i_rf_ready) o_cnt_en <= 1; else
|
|
if (o_cnt_done) o_cnt_en <= 0;
|
|
o_cnt <= o_cnt + { 2'b0, o_cnt_en };
|
|
end else if (W == 1) begin
|
|
o_cnt <= o_cnt + {2'd0,cnt_r[3]};
|
|
cnt_r <= {cnt_r[2:0],(cnt_r[3] & !o_cnt_done) | (i_rf_ready & !o_cnt_en)};
|
|
end
|
|
if (i_rst) begin
|
|
if (RESET_STRATEGY != "NONE") begin
|
|
o_cnt <= 3'd0;
|
|
if (W == 1)
|
|
cnt_r <= 4'b0000;
|
|
else if (W == 4)
|
|
o_cnt_en <= 1'b0;
|
|
end
|
|
end
|
|
end
|
|
|
|
always @(*)
|
|
if (W == 1)
|
|
o_cnt_en = |cnt_r;
|
|
else if (W == 4)
|
|
cnt_r = 4'b1111;
|
|
|
|
assign o_ctrl_trap = WITH_CSR & (i_e_op | i_new_irq | misalign_trap_sync);
|
|
|
|
generate
|
|
if (WITH_CSR) begin : gen_csr
|
|
reg misalign_trap_sync_r;
|
|
|
|
//trap_pending is only guaranteed to have correct value during the
|
|
// last cycle of the init stage
|
|
wire trap_pending = WITH_CSR & ((take_branch & i_ctrl_misalign & !ALIGN) |
|
|
(i_dbus_en & i_mem_misalign));
|
|
|
|
always @(posedge i_clk) begin
|
|
if (i_ibus_ack | o_cnt_done | i_rst)
|
|
misalign_trap_sync_r <= !(i_ibus_ack | i_rst) & ((trap_pending & o_init) | misalign_trap_sync_r);
|
|
end
|
|
assign misalign_trap_sync = misalign_trap_sync_r;
|
|
end else begin : gen_no_csr
|
|
assign misalign_trap_sync = 1'b0;
|
|
end
|
|
endgenerate
|
|
endmodule
|